PRO1™ Switched PIPS C1W08HC 3.3kW - 7.3kW (8) C13 outlets Rack PDU

Family Description
The Server Technology® PRO1 Switched Rack PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO1 Switched "Master" PDU can be connected to as many as three PRO1 Switched "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.






ENA-1339-11P_back.pngENA-1339-11P_RENDER.png








Key Features
Network_Monitoring_test.png

NETWORK MONITORING

The PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.

HotSwappable_test.pngHOT-SWAP NETWORK CARD

Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit.

MultiLink_Expansion_test.pngSTAR MULTI-LINKING

PRO2 provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.







Enviromental_Monitoring.pngTEMPERATURE/HUMIDITY MONITORING

PRO2 Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.

Input_Current_Monitor.pngAUTO-FLIP CURRENT DISPLAY

Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.

PIPS.pngPER-INLET POWER SENSING

Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.







Branch_Circuit_Protection.pngBRANCH CIRCUIT PROTECTION

PRO2 meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.

Outlet_Control.pngALTERNATING-PHASE OUTLETS

3-phase power is wired in an alternating fashion per outlet for simplified load balancing, reduced cord lengths, and better airflow.

High_Retention_Outlets.pngALTERNATING-PHASE OUTLETS

3-phase power is wired in an alternating fashion per outlet for simplified load balancing, reduced cord lengths, and better airflow.







High-Temp.pngHIGH TEMPERATURE RATING

This product has been tested and approved for safe and reliable operation in 60°C (140°F) data center environments.

Flexible_Mounting.png

FLEXIBLE MOUNTING

PRO2 includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).

PDU_Colors.pngCOLOR IDENTIFICATION

Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.







Cisco_Dev.pngCISCO ENERGYWISE¹ COMPLIANT

PRO2 meets the requirements set forth by Cisco Systems, Inc. for its EnergyWise program for monitoring of device energy. EnergyWise is a registered trademark of Cisco Systems, Inc.







Family Specifications

Branch Monitoring:Sense

Branch Overcurrent Protection:5 kAIC

Branch Overcurrent Protection Type:Circuit Breaker: 2-pole

Dual Input:No

High Retention Outlets:Yes

Input Current Display:Auto-Orient

Input Monitoring:PIPS

Locking Outlets:Yes

Max Operating Temperature:60 °C

Fast Movers:No

Mounting:1U Horizontal

Outlet Monitoring:None

PDU Platform: PRO1

Power Pivot Input:No

Product Height (inch):1.75

Product Height (mm):45

Product Max Depth (inch):7.0

Product Max Depth (mm):178

Product Nominal Depth (inch):7.0

Product Nominal Depth (mm):178

Product Width (inch):17.2

Product Width (mm):437



Model No.
C1W08HC-0ABA2BAC (SWITCHED)

REQUIRES PTCORD-L1, -L2, -L3, -L4, -L5, -L6, OR –L7

C1W08HC-2CBA2BAC (SWITCHED)
C1W08HC-0ABA2BAC.jpgC1W08HC-2CBA2BAC.jpg


C1W08HC-EPBA2BAC (SWITCHED)


C1W08HC-EPBA2BAC.jpg




品牌
server technology
型号
C1W08HC-0ABA2BAC、C1W08HC-2CBA2BAC、C1W08HC-EPBA2BAC
简介
PRO1™ Switched PIPS C1W08HC 3.3kW - 7.3kW (8) C13 outlets Rack PDU
类型
SWITCHED